|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
POWER ENTRY MODULES WITH LINE FILTER 5120 Actual information about approvals can be found on http://www.schurter.com/approvals Front or rear mounting Protection class I Rear mounting with integrated thread Protection class I Front or rear mounting Protection class II C14 C18 70 C 70 C Standard- or Medical-Filter Describtion - Panel Mount: Screw-on version from front or rear side - 2 Functions: Inlet, protection class I or II, Line filter in standard and medical version Quick connect terminals 6.3 x 0.8 mm Characteristics - Compact high performance filter - Qualified for use in equipment according IEC/EN 60950 Other versions on request - class X1 capacitor for enhanced surge withstand voltage - medical version M80 Technical Data Ratings IEC Ratings UL/CSA Leakage current Dielectric Strength 1 - 10 A @ Ta 40 C / 250 VAC; 50 Hz 1 - 15 A @ Ta 40 C / 250 VAC; 60 Hz standard < 0.5 mA (250 V / 60 Hz) medical < 5 A (250 V / 60 Hz) > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (1 min) -25 C to 85 C 25/085/21, IEC 60068-1 from front side IP 40 acc. to IEC 60529 Suitable for appliances with protection class I or II acc. to IEC 61140 Quick connect terminals 6.3 x 0.8 mm Screw-on from rear side to 2.5 mm Mounting screw torque max 0.5 Nm Thermoplastic, Black, UL 94V-0 Appliance-inlet /-outlet C14 or C18 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 10 A, Protection class I or II Standard and medical version, IEC 60939, IEC 60601-1, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details POWER ENTRY MODULES WITHOUT LINE FILTER Line filter Allowable operation temp. Climatic Category Degree of Protection Protection Class Terminals Panel Thickness s Material: Housing Dimensions Front or rear side mounting for screws with nuts or blind rivets (panel cutout for frontside mounting) 48.6 40 12 54.5 39.5 3 12 28.8 +0.50 0 24.6 4.4 max.R3 8.5 3.6 M3 40 0.10 Dimensions for class I version also apply to class II 2 www.schurter.com 21.3 +0.50 0 POWER ENTRY MODULES WITH LINE FILTER 5120 Rear side mounting with pre-formed, threaded holes for M3 screws (panel cutout for rear side mounting) 48.6 40 12 54.5 39.5 3 12 30.5 +0.50 0 24.6 4.4 M3 3.6 40 0.10 Dimensions for class II version also apply to class I Technical Data of Filter-Components Rated Current Filter-Type [A] 1 2 4 6 10 15 1 2 4 6 10 15 1 2 4 6 10 15 Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Bleed Resistor Version Bleed Resistor Version Bleed Resistor Version Bleed Resistor Version Bleed Resistor Version Bleed Resistor Version Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Inductances Capacitance Capacitance L [mH] CX [nF] CY [nF] 12.0 5.2 2.0 0.8 0.4 0.1 12.0 5.2 2.0 0.8 0.4 0.1 12.0 5.2 2.0 0.8 0.4 0.1 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 R [M] 1 1 1 1 1 1 1 1 1 1 1 1 15 A version only according UL/CSA Diagrams Standard version Bleed Resistor version Medical version M5 Medical version M5, prot. class II 1) Line 2) Load 1) Line 2) Load 1) Line 2) Load 1) Line 2) Load 3 www.schurter.com 22.5 max.R3 +0.50 0 POWER ENTRY MODULES WITH LINE FILTER 5120 Attenuation loss Standard version - - - - differential mode _____ common mode 1A 2A 4A 6A 10 A 15 A Medical version (M5) 1A 2A 4A 6A 10 A 15 A Variants Order Number 5120.0000.0 5120.0001.0 5120.0003.0 5120.0004.0 5120.0006.0 5120.0007.0 5120.1000.0 5120.1001.0 5120.1003.0 5120.1004.0 5120.1006.0 5120.1007.0 5120.0200.0 5120.0201.0 5120.0203.0 5120.0204.0 5120.0206.0 5120.0207.0 Rated Current Filter-Type [A] 1 2 4 6 10 15 1 2 4 6 10 15 1 2 4 6 10 15 Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Standard Version Bleed Resistor Version Bleed Resistor Version Bleed Resistor Version Bleed Resistor Version Bleed Resistor Version Bleed Resistor Version Panel mounting Screw-on version from front or rear side for screws with nuts, or rivets Screw-on version from front or rear side for screws with nuts, or rivets Screw-on version from front or rear side for screws with nuts, or rivets Screw-on version from front or rear side for screws with nuts, or rivets Screw-on version from front or rear side for screws with nuts, or rivets Screw-on version from front or rear side for screws with nuts, or rivets Screw-on from rear side with pre-formed, threaded holes for M3 screws Screw-on from rear side with pre-formed, threaded holes for M3 screws Screw-on from rear side with pre-formed, threaded holes for M3 screws Screw-on from rear side with pre-formed, threaded holes for M3 screws Screw-on from rear side with pre-formed, threaded holes for M3 screws Screw-on from rear side with pre-formed, threaded holes for M3 screws Screw-on version from front or rear side for screws with nuts, or rivets Screw-on version from front or rear side for screws with nuts, or rivets Screw-on version from front or rear side for screws with nuts, or rivets Screw-on version from front or rear side for screws with nuts, or rivets Screw-on version from front or rear side for screws with nuts, or rivets Screw-on version from front or rear side for screws with nuts, or rivets Protection Class I I I I I I I I I I I I I I I I I I 4 www.schurter.com POWER ENTRY MODULES WITH LINE FILTER 5120 Order Number 5120.1200.0 5120.1201.0 5120.1203.0 5120.1204.0 5120.1206.0 5120.1207.0 5120.0300.0 5120.0301.0 5120.0303.0 5120.0304.0 5120.0306.0 5120.0307.0 5120.1300.0 5120.1301.0 5120.1303.0 5120.1304.0 5120.1306.0 5120.1307.0 5120.0301.1 5120.0303.1 5120.0304.1 5120.1300.1 5120.1301.1 5120.1303.1 5120.1304.1 5120.1306.1 Rated Current Filter-Type [A] 1 2 4 6 10 15 1 2 4 6 10 15 1 2 4 6 10 15 2 4 6 1 2 4 6 10 Bleed Resistor Version Bleed Resistor Version Bleed Resistor Version Bleed Resistor Version Bleed Resistor Version Bleed Resistor Version Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Medical Version (M5) Panel mounting Screw-on from rear side with pre-formed, threaded holes for M3 screws Screw-on from rear side with pre-formed, threaded holes for M3 screws Screw-on from rear side with pre-formed, threaded holes for M3 screws Screw-on from rear side with pre-formed, threaded holes for M3 screws Screw-on from rear side with pre-formed, threaded holes for M3 screws Screw-on from rear side with pre-formed, threaded holes for M3 screws Screw-on version from front or rear side for screws with nuts, or rivets Screw-on version from front or rear side for screws with nuts, or rivets Screw-on version from front or rear side for screws with nuts, or rivets Screw-on version from front or rear side for screws with nuts, or rivets Screw-on version from front or rear side for screws with nuts, or rivets Screw-on version from front or rear side for screws with nuts, or rivets Screw-on from rear side with pre-formed, threaded holes for M3 screws Screw-on from rear side with pre-formed, threaded holes for M3 screws Screw-on from rear side with pre-formed, threaded holes for M3 screws Screw-on from rear side with pre-formed, threaded holes for M3 screws Screw-on from rear side with pre-formed, threaded holes for M3 screws Screw-on from rear side with pre-formed, threaded holes for M3 screws Screw-on version from front or rear side for screws with nuts, or rivets Screw-on version from front or rear side for screws with nuts, or rivets Screw-on version from front or rear side for screws with nuts, or rivets Screw-on from rear side with pre-formed, threaded holes for M3 screws Screw-on from rear side with pre-formed, threaded holes for M3 screws Screw-on from rear side with pre-formed, threaded holes for M3 screws Screw-on from rear side with pre-formed, threaded holes for M3 screws Screw-on from rear side with pre-formed, threaded holes for M3 screws Protection Class I I I I I I I I I I I I I I I I I I II II II II II II II II 15 A version only according UL/CSA Packaging unit 10 Pcs 5 www.schurter.com POWER ENTRY MODULES WITH LINE FILTER 5120 ACCESSORIES Insulating cover The terminals of the Schurter appliance couplers can be protected against unintentional contact by the use of an insulation cover. They are made of flexible thermoplastic (UL 94V-0, black) and can be easily mounted from the rear to the corresponding appliance couplers. Order Numbers suitable for 0859.0048 5120 Cord retaining kits For protection against loosening or accidental disconnection of the plug connector. Can also be mounted later. The correct kit type (A-M) for each combination of fixed and free components is shown in the selection chart on page 172. The corresponding Order No. for each kit type is shown in the smaller chart. Horizontal flanged components are secured to the panel using the kit supplied. Vertical flanged or snap-in components require additional drilling for the cord retaining kit as shown in the diagrams below. Each cord retaining kit consists of: 1 Stainless steel retaining clip 2 Nickel plated brass pillars 2 Nickel plated brass nuts 2 Nickel plated beryllium copper crinkle washers Order Numbers Connector suitable for 5120 Front panel mounting 5120 Rear side mounting Panel thickness < 3 mm 5120 Rear side mounting Panel thickness > 5 mm 4700.0005 4700.0007 4782.0000 4782.0100 4782.0000 4782.0100 x x x Cut-aways or countersinks on pillars to face inwards. 6 www.schurter.com |
Price & Availability of 512000000 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |